Explore our Data Centers

MAIN Data Centers are fully redundant, meet the highest security requirements and ensure business continuity.

We hold ISO 9001 and ISO 27001 certificates.
The facilities are powered 100% by renewable energy

MAIN DC1 (MAIN G9)

MAIN G9 Data Center is located on 7/9, Giełdowa Street in Warsaw, near the city center. It meets the highest standards in security, connectivity and cooling. It is fully redundant, based on Enterprise-class hardware.

The facility meets Tier III requirements for performance, reliability, and resilience against unplanned outages. It is powered 100% by renewable energy sources.

DC1 ensures business continuity of the High Availability environments located there, and thanks to the DWDM connection with geographically remote MAIN DC2 and DC3 facilities, it enables a range of Recovery Center services.

Check directions

Kolokacja - serwery w chmurze MAIN
Kolokacja - serwery w chmurze MAIN
Kolokacja serwera w chmurze MAIN
Disaster Recovery Center
Kolokacja - serwery w chmurze MAIN
Kolokacja - serwery w chmurze MAIN
Kolokacja - serwery w chmurze MAIN
Kolokacja serwera w chmurze MAIN
Disaster Recovery Center
Kolokacja - serwery w chmurze MAIN

MAIN DC2 (Netia HEART)

The facility is located close to the business center of Warsaw at 13, Poleczki Street in Mokotów, connected to our primary location via a DWDM link. This modern Data Center meets the highest standards, ensuring the security of stored resources.

DC2 is equipped with  two independent power lines, an ultra-modern fire suppression system, and air conditioning with N+1 redundancy free cooling, guaranteeing uninterrupted operation and data security.

The Data Center is 100% powered by renewable energy sources.

Check directions

MAIN DC3 (Equinix IBX WA3)

As a partner of Equinix, we use colocation space at Equinix International Business Exchange™ (IBX®), the most modern data center in Poland, located in Warsaw at 213, Jerozolimskie Avenue.

The facility was built according to the latest standards in Data Center construction and uses 100% renewable energy. It provides private direct connections within Equinix Fabric™, which offer low latency links to public cloud providers worldwide.

Disaster Recovery Center
Relokacja serwerowni
Disaster Recovery Center
Relokacja serwerowni

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

As a partner of Equinix, we also utilize colocation space at the Equinix FR2 Data Center in Frankfurt am Main in Germany.

Thanks to its strategic location in the heart of Europe, FR2 provides direct connections to over 280 network service providers and access to the world’s largest internet exchange point – DE-CIX Frankfurt.

The facility is powered 100% by renewable energy sources.

100% Renewable Energy

All our facilities are powered entirely by 100% renewable energy sources (RES).

MAIN Data Centers parameters

MAIN DC1 (MAIN G9)

Main server room:

  • Space: 154 m²
  • 54 server racks 42U
  • 4 rows (14, 14, 13 i 14) of 42U server racks 42U

Private Box P1 and P2:

  • Space: 18 and 20 m²
  • 4-6 server racks 42U

MAIN DC2 (Netia HEART)

  • 20 racks 42U

MAIN DC3 (Equinix IBX WA3)

  • Space: 20 m²
  • 10 racks 42U

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Global IBX facility uptime >99.999%

MAIN DC1 (MAIN G9)

  • Facility protection 24/7
  • Multi-zone access control system to prevent unauthorized entry into the facility and designated rooms
  • Fire alarm system
  • Voice Evacuation System
  • CCTV system – continuous, high definition video surveillance outside and inside the facility
  • On-demand video preview of the area where the client’s resources are located
  • Building parameters monitoring system:
    – power supply,
    – environmental parameters,
    – air conditioning,
    – alarm system,
    – early fire detection system with precise location of its source.

MAIN DC2 (Netia HEART)

  • Gas suppression – new installation in all chambers,
  • 80 cylinders with IG-541 inert gas mixture,
  • Produced by Tyco – market leader, certifications: VdS, LM, FM, LPCB, CNBOP,
  • iFlow system – increased equipment safety,
  • FIRST IN POLAND noise reduction system protecting disks during gas release.

MAIN DC3 (Equinix IBX WA3)

  • VESDA smoke detection system
  • Fire suppression water mist system
  • 24/7 security
  • Access control system (proximity cards and biometrics)
  • CCTV monitoring with 90-day archive storage

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Physical: Man trap entry
  • Human: 24/7 on-site security officers
  • Electronic: Card readers, biometric readers, CCTV surveillance with 90-day video retention, motion detection
  • Fire suppression: VESDA, Hi-Fog, optical fire detectors

Redundant, automatic, multilevel power supply system ensuring constant access to electricity:

  • 2 independent power supply tracks from 15 kV MV network:
    – transformer I – 1 MW
    – transformer II – 1 MW,
  • 2 power generators (for the needs of the Data Center)
    – generator I – 450 kVA,
    – generator II – 450 kVA,
  • 2 modular UPS systems (N+1) working only for the needs of server rack cabinets.

MAIN DC2 (Netia HEART)

  • 2 independent power lines + UPS with batteries + Generators,
  • N+1 redundancy,
  • Battery backup for at least 25 minutes,
  • Emergency and guaranteed power supply.

MAIN DC3 (Equinix IBX WA3)

  • Power supply: 42 kVA (4.2 kVA per cabinet),
  • UPS units in a “distributed” redundant configuration,
  • 4 generators of 1600 kVA each.

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Power supply 3.0 – 6.0 kVA per cabinet
  • 2 UPS units in a distributed N+1 redundant configuration

MAIN DC1 (MAIN G9)

Server rooms are equipped with the Emerson Network Power air conditioning system.

  • The system is based on cooling cabinets that supply cooled air to the technical floor.
  • We provide constant monitoring of environmental parameters (temperature and humidity) in server rooms.

MAIN DC2 (Netia HEART)

  • STULZ CyberAir 3
  • Free Cooling
  • Cold aisle containment
  • 500 kW + 100 kW cooling capacity
  • High power density possible

MAIN DC3 (Equinix IBX WA3)

  • Cooling devices in an N+1 configuration
  • CRAH system (Computer Room Air Handler)

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Screw compressor and turbo compressor chillers

MAIN DC1 (MAIN G9)

Fiber optic connectors to 3 independent telecommunication manholes

The facility has connections to the following operators:

  • Orange
  • Netia
  • Equinix Internet Exchange Warsaw
  • Cogent Communications
  • StarNet Telecom
  • eTOP

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Interconnection: Equinix Fabric®, Fabric Cloud Router, Equinix Precision Time®, Equinix Internet Exchange®, Equinix Internet Access, Metro Connect®, Cross Connects

MAIN DC1 (MAIN G9)

  • PN-EN ISO 9001:2015
  • PN-EN ISO 27001:2023

In the following capacity:
Sale and provision of telecommunications services, including colocation, hosting and data transmission services, as well as Internet access and cloud services.

View the certificates (PDF)

MAIN DC2 (Netia HEART)

  • ISO 9001:2015

In the following capacity:
Provision of telecommunications services, ICT security services, colocation services, cloud computing services, call center services, and specialized telecommunications services for the railway market.

  • PN-EN ISO/IEC 27001:2017-06

In the following capacity:
Provision of colocation and cloud computing services for the business market, as well as cybersecurity services.

MAIN DC3 (Equinix IBX WA3)

  • Climate Neutral Data Centre Pact
  • Cyber Essentials
  • ISO 14001, ISO 22301, ISO 27001, ISO 45001, ISO 50001, ISO 9001
  • PCI DSS
  • SOC 1 Type II
  • SOC 2 Type II

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • ISO 22301, ISO 27001, ISO 45001, ISO 9001, PCI DSS
  • SOC 1 Type II
  • SOC 2 Type II
    Cyber Essentials, EN 50600 & TSI (FR2.3-6), TISAX, EU Code of Conduct, Critical National Infrastructure
  • Green by Design: ISO 14001, ISO 50001, covered by 100% renewable energy
COLOCATION
SECURITY
POWER SUPPLY
COOLING
CONNECTIVITY
CERTIFICATES

MAIN DC1 (MAIN G9)

Main server room:

  • Space: 154 m²
  • 54 server racks 42U
  • 4 rows (14, 14, 13 i 14) of 42U server racks 42U

Private Box P1 and P2:

  • Space: 18 and 20 m²
  • 4-6 server racks 42U

MAIN DC2 (Netia HEART)

  • 20 racks 42U

MAIN DC3 (Equinix IBX WA3)

  • Space: 20 m²
  • 10 racks 42U

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Global IBX facility uptime >99.999%

MAIN DC1 (MAIN G9)

  • Facility protection 24/7
  • Multi-zone access control system to prevent unauthorized entry into the facility and designated rooms
  • Fire alarm system
  • Voice Evacuation System
  • CCTV system – continuous, high definition video surveillance outside and inside the facility
  • On-demand video preview of the area where the client’s resources are located
  • Building parameters monitoring system:
    – power supply,
    – environmental parameters,
    – air conditioning,
    – alarm system,
    – early fire detection system with precise location of its source.

MAIN DC2 (Netia HEART)

  • Gas suppression – new installation in all chambers,
  • 80 cylinders with IG-541 inert gas mixture,
  • Produced by Tyco – market leader, certifications: VdS, LM, FM, LPCB, CNBOP,
  • iFlow system – increased equipment safety,
  • FIRST IN POLAND noise reduction system protecting disks during gas release.

MAIN DC3 (Equinix IBX WA3)

  • VESDA smoke detection system
  • Fire suppression water mist system
  • 24/7 security
  • Access control system (proximity cards and biometrics)
  • CCTV monitoring with 90-day archive storage

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Physical: Man trap entry
  • Human: 24/7 on-site security officers
  • Electronic: Card readers, biometric readers, CCTV surveillance with 90-day video retention, motion detection
  • Fire suppression: VESDA, Hi-Fog, optical fire detectors

Redundant, automatic, multilevel power supply system ensuring constant access to electricity:

  • 2 independent power supply tracks from 15 kV MV network:
    – transformer I – 1 MW
    – transformer II – 1 MW,
  • 2 power generators (for the needs of the Data Center)
    – generator I – 450 kVA,
    – generator II – 450 kVA,
  • 2 modular UPS systems (N+1) working only for the needs of server rack cabinets.

MAIN DC2 (Netia HEART)

  • 2 independent power lines + UPS with batteries + Generators,
  • N+1 redundancy,
  • Battery backup for at least 25 minutes,
  • Emergency and guaranteed power supply.

MAIN DC3 (Equinix IBX WA3)

  • Power supply: 42 kVA (4.2 kVA per cabinet),
  • UPS units in a “distributed” redundant configuration,
  • 4 generators of 1600 kVA each.

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Power supply 3.0 – 6.0 kVA per cabinet
  • 2 UPS units in a distributed N+1 redundant configuration

MAIN DC1 (MAIN G9)

Server rooms are equipped with the Emerson Network Power air conditioning system.

  • The system is based on cooling cabinets that supply cooled air to the technical floor.
  • We provide constant monitoring of environmental parameters (temperature and humidity) in server rooms.

MAIN DC2 (Netia HEART)

  • STULZ CyberAir 3
  • Free Cooling
  • Cold aisle containment
  • 500 kW + 100 kW cooling capacity
  • High power density possible

MAIN DC3 (Equinix IBX WA3)

  • Cooling devices in an N+1 configuration
  • CRAH system (Computer Room Air Handler)

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Screw compressor and turbo compressor chillers

MAIN DC1 (MAIN G9)

Fiber optic connectors to 3 independent telecommunication manholes

The facility has connections to the following operators:

  • Orange
  • Netia
  • Equinix Internet Exchange Warsaw
  • Cogent Communications
  • StarNet Telecom
  • eTOP

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • Interconnection: Equinix Fabric®, Fabric Cloud Router, Equinix Precision Time®, Equinix Internet Exchange®, Equinix Internet Access, Metro Connect®, Cross Connects

MAIN DC1 (MAIN G9)

  • PN-EN ISO 9001:2015
  • PN-EN ISO 27001:2023

In the following capacity:
Sale and provision of telecommunications services, including colocation, hosting and data transmission services, as well as Internet access and cloud services.

View the certificates (PDF)

MAIN DC2 (Netia HEART)

  • ISO 9001:2015

In the following capacity:
Provision of telecommunications services, ICT security services, colocation services, cloud computing services, call center services, and specialized telecommunications services for the railway market.

  • PN-EN ISO/IEC 27001:2017-06

In the following capacity:
Provision of colocation and cloud computing services for the business market, as well as cybersecurity services.

MAIN DC3 (Equinix IBX WA3)

  • Climate Neutral Data Centre Pact
  • Cyber Essentials
  • ISO 14001, ISO 22301, ISO 27001, ISO 45001, ISO 50001, ISO 9001
  • PCI DSS
  • SOC 1 Type II
  • SOC 2 Type II

MAIN DC4 (Equinix IBX FR2 – Frankfurt)

  • ISO 22301, ISO 27001, ISO 45001, ISO 9001, PCI DSS
  • SOC 1 Type II
  • SOC 2 Type II
    Cyber Essentials, EN 50600 & TSI (FR2.3-6), TISAX, EU Code of Conduct, Critical National Infrastructure
  • Green by Design: ISO 14001, ISO 50001, covered by 100% renewable energy

Visit our Data Center

Would you like to see our Data Centers?

Quality in accordance with requirements

We hold certificates:

  • PN-EN ISO 9001:2015
  • PN-EN ISO/IEC 27001:2023

Scope: Sale and provision of telecommunications services, including colocation, hosting and data transmission services, as well as Internet access and cloud services.

View the certificates (PDF)

MAIN Sp. z o.o. is a part of EIP Group, which is known for offering high quality, professional and comprehensive services.

The Group consits of companies involved in the implementation of IT solutions, supply of IT hardware, ERP/CRM/E-Commerce software, Data Center and cloud services, management and design of LAN/WAN/SDWAN networks, as well as IT security.

The combination of the latest key technologies from global manufacturers with years of experience in the market makes EIP an effective Polish IT integrator.

Disaster Recovery Center

We use geographically separated Data Centers to offer Disaster Recovery services and ensure business continuity for our clients.

The facilities are connected via independent routes. We also use our own DWDM devices with encryption of transmitted data.

Additionally, thanks to solutions such as VMware vCloud and Site Recovery Manager we build High Availability environments.

Learn more

Redundancy of resources

Redundancy helps eliminate single points of failure within the IT infrastructure. It ensures business continuity, i.e. the uninterrupted operation of IT systems and uninterrupted access to data such as customer orders, inventory levels, or financial and accounting data.

MAIN Data Centers provide redundancy at all levels: power supply, network, hardware, software and technical staff.

Let's get in touch

Do you have questions or would like to learn how MAIN can support your business?

Michał Kaczorowski - IFS Cloud

Michał Kaczorowski
Head of Infrastructure

We guarantee

EXPERIENCED TEAM

Thanks to many years of experience we provide our clients with uninterrupted services.

TRANSPARENCY

We base every cooperation on mutual respect and openness. We always prepare an exit plan.

24/7 SUPPORT

Dedicated technical supervisor, project manager and a team of specialists are there to assist you.